Physical testing in patients with acute whiplash-associated disorders: A within session test-retest reliability study

E Anarte-Lazo, C Rodriguez-Blanco*, D Falla, C Bernal-Utrera

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

75 Downloads (Pure)

Abstract

BACKGROUND: People with whiplash-associated disorders (WAD) commonly present with a variety of physical impairments. However, the reliability of physical tests has not been established for patients with acute WAD.

OBJECTIVE: To assess test-retest reliability of different physical tests in acute WAD.

DESIGN: Intra-rater test-retest reliability.

METHODS: Patients with acute WAD were recruited. Physical tests were used to evaluate articular, muscular and neural systems in two blocks of measurements separated by 10 min. Bland-Altman plots were performed to assess intrarater agreement, which included calculation of the mean difference (d) between rates, the 95% CI for d, the standard deviation of the differences and the 95% limits of agreement. Reliability was calculated via the standard error of measurement, the minimal detectable change, percent of agreement, the intraclass-correlation coefficient, and kappa coefficient.

RESULTS: 47 patients participated. Test-retest reliability was excellent or good for almost all measures, except for extension ROM, ULTT for the radial nerve, and active cervical extension and upper cervical rotation performed in 4-point kneeling, which presented moderate reliability. Systematic bias was found in cervical ROM in flexion, left and right lateral-flexion, left and right rotation; left ULTT for radial nerve; right trapezius, suboccipitalis and temporalis muscles, left temporalis; C3, both sides of C1-C2, left C3-C4.

CONCLUSION: The majority of physical tests achieved good or excellent test-retest intra-rater reliability when tested in patients with acute WAD. Findings must be considered with caution for those tests which demonstrated systematic bias. Additional research is warranted to evaluate inter-rater reliability.

Original languageEnglish
Article number102738
Number of pages9
JournalMusculoskeletal Science and Practice
Volume64
Early online date28 Feb 2023
DOIs
Publication statusPublished - Apr 2023

Bibliographical note

Copyright © 2023 The Authors. Published by Elsevier Ltd.

Keywords

  • Whiplash-associated disorders
  • Physical testing
  • Test-retest reliability
  • Neuromusculoskeletal disorders

Fingerprint

Dive into the research topics of 'Physical testing in patients with acute whiplash-associated disorders: A within session test-retest reliability study'. Together they form a unique fingerprint.