Inter-rater and intra-rater reliability of ultrasound imaging for measuring quadriceps muscle and non-contractile tissue thickness of the anterior thigh

Mechelli Filippo, Arendt-Nielsen Lars, Stokes Maria, Agyapong-Badu Sandra

Research output: Contribution to journalArticlepeer-review

Abstract

Biomedical Physics & Engineering Express
Institute of Physics and Engineering in Medicine logo




NOTE
Inter-rater and intra-rater reliability of ultrasound imaging for measuring quadriceps muscle and non-contractile tissue thickness of the anterior thigh
Mechelli Filippo1,2, Arendt-Nielsen Lars, Stokes Maria3,4 and Agyapong-Badu Sandra5

Published 28 March 2019 • © 2019 IOP Publishing Ltd
Biomedical Physics & Engineering Express, Volume 5, Number 3
Citation Mechelli Filippo et al 2019 Biomed. Phys. Eng. Express 5 037002
DownloadArticle PDF
Figures
References
Download PDF
243 Total downloads
99 total citations on Dimensions.Article has an altmetric score of 1
Turn on MathJax
Get permission to re-use this article

Share this article

Share this content via email
Share on Facebook (opens new window)
Share on Twitter (opens new window)
Share on Mendeley (opens new window)
Article information
Abstract
Objective: To determine intra-rater and inter-rater reliability of ultrasound imaging for measuring muscle and non-contractile (subcutaneous fat and perimuscular fascia) tissue thickness of the anterior thigh. Approach: Ultrasound imaging has been used for clinical research to assess the morphology and cross-sectional area of muscles and other musculoskeletal structures. Repeatability of measurements with the ultrasound imaging technique between operators and test re-test reliability are important and need to be established for specific muscles. Twenty-four healthy moderately active adults (aged 36–64 years), underwent B-mode ultrasound imaging by two investigators. The anterior thighs were scanned at a site two-thirds of the distance between the antero-superior iliac spine and the superior pole of the patella. Intraclass Correlation Coefficients (ICCs, model 3, 1 for inter-rater and 3, 2 for intra-rater reliability between-days) with 95% confidence intervals (CI) was used to assess reliability. Main results: Inter-rater reliability of ultrasound imaging measurements were ICC3, 1 of 0.98 (95% CI: 0.95–0.99) for muscle thickness, 0.81 (95% CI: 0.60–0.91) for subcutaneous fat, 0.78 (95% CI: 0.56–0.90) for non-contractile tissue (subcutaneous fat combined with perimuscular fascia), and 0.70 (95% CI: 0.42–0.86) for perimuscular fascia. Intra-rater reliability values were ICC3, 2 0.96 (95% CI: 0.90–0.98) for muscle thickness, 0.99 (95% CI: 0.97–0.99) for subcutaneous fat, 0.98 (95% CI: 0.96–0.99) for non-contractile tissue, and −0.02 (95% CI: −0.41–0.38) for perimuscular fascia. Significance: The present findings indicate very high inter-rater and intra-rater reliability of ultrasound imaging thickness measurements of the quadriceps muscles and non-contractile tissue of the anterior thigh, while perimuscular fascia measurements alone were not reliable between days.
Original languageEnglish
Article number037002
JournalBiomedical Physics & Engineering Express
Volume5
DOIs
Publication statusPublished - 28 Mar 2019

Fingerprint

Dive into the research topics of 'Inter-rater and intra-rater reliability of ultrasound imaging for measuring quadriceps muscle and non-contractile tissue thickness of the anterior thigh'. Together they form a unique fingerprint.

Cite this