Energy calibration through X-ray absorption of the DECAL sensor, a monolithic active pixel sensor prototype for digital electromagnetic calorimetry and tracking

Lucian Fasselt*, Philip Patrick Allport, Seddik Benhammadi, Robert Ross Bosley, Jens Dopke, Samuel Flynn, Laura Gonella, Nicola Guerrini, Cigdem Issever, Kostas Nikolopoulos, Ioannis Kopsalis, Peter Philips, Tony Price, Iain Sedgwick, Giulio Villani, Matt Warren, Nigel Watson, Hannsjörg Weber, Alasdair Winter, Fergus WilsonSteven Worm, Zhige Zhang

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

56 Downloads (Pure)

Abstract

In calorimetry, the predominant detection principle is to measure the energy deposited by particles within a shower initiated by an incident particle. An alternative concept is a sampling calorimeter where the highly granular active layers rather measure the number of secondary particles in the shower by detecting hits through binary readout similar to sensors for tracking applications. In this context, the DECAL sensor is a fully-depleted monolithic active pixel sensor prototype with reconfigurable readout for digital electromagnetic calorimetry and tracking. Its 64 × 64 pixels with a pitch of 55 µm are fabricated in a modified TowerJazz 180 nm CMOS imaging process using a 25 µm epitaxial silicon layer. The readout at 40 MHz is configurable in counting hits in the sensor grouped as either 64 strips or 4 pads. In this article, we present the energy calibration of this sensor using a gamma source of americium-241 as well as X-ray fluorescence at various wavelengths. The uniformity of the pixel responses is shown, allowing the summation of counts across all pixels. By that, two standalone energy calibration methods are developed that describe the X-ray absorption in the energy range of 4–60 keV and agree with each other. The signal pulse height is related to the absorbed photon energy with a 5.54 ± 0.37 mV/keV scale which corresponds to a conversion gain of cg = 19.95 ± 1.32 μV/e. The relative energy resolution for photon absorption is found to be σE/E = 11.8 ± 3.0%. The absolute counts observed with the DECAL sensor agree with expectations and substantiate the assumption of a fully depleted epitaxial layer. The understanding of the photon absorption is an important input for further development of the sensor towards a multi-layer calorimeter.
Original languageEnglish
Article number1231336
Number of pages10
JournalFrontiers in Physics
Volume11
DOIs
Publication statusPublished - 17 Oct 2023

Bibliographical note

Funding:
The project funding received from the UK Research and Innovation—STFC Grant No. ST/N002911/1, the Birmingham Particle Physics Consolidated Grants: ST/N000463/1, ST/N001125/1, ST/P005888/1 and the European Union’s Horizon 2020 Research and Innovation programme under Grant Agreement No. 654168. This publication was funded by Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)—491245950.

Keywords

  • complementary metal oxide semiconductor (CMOS)
  • depleted monolithic active pixel sensor (DMAPS)
  • tracking
  • digital calorimetry
  • ECAL
  • X-ray fluorescence
  • energy calibration
  • particle physics

Fingerprint

Dive into the research topics of 'Energy calibration through X-ray absorption of the DECAL sensor, a monolithic active pixel sensor prototype for digital electromagnetic calorimetry and tracking'. Together they form a unique fingerprint.

Cite this