TY - JOUR
T1 - Effect of using the same vs different order for second readings of screening mammograms on rates of breast cancer detection
T2 - a randomized clinical trial
AU - Taylor-Phillips, Sian
AU - Wallis, Matthew G
AU - Jenkinson, David
AU - Adekanmbi, Victor
AU - Parsons, Helen
AU - Dunn, Janet
AU - Stallard, Nigel
AU - Szczepura, Ala
AU - Gates, Simon
AU - Kearins, Olive
AU - Duncan, Alison
AU - Hudson, Sue
AU - Clarke, Aileen
PY - 2016/5/10
Y1 - 2016/5/10
N2 - IMPORTANCE: Interpreting screening mammograms is a difficult repetitive task that can result in missed cancers and false-positive recalls. In the United Kingdom, 2 film readers independently evaluate each mammogram to search for signs of cancer and examine digital mammograms in batches. However, a vigilance decrement (reduced detection rate with time on task) has been observed in similar settings.OBJECTIVE: To determine the effect of changing the order for the second film reader of batches of screening mammograms on rates of breast cancer detection.DESIGN, SETTING, AND PARTICIPANTS: A multicenter, double-blind, cluster randomized clinical trial conducted at 46 specialized breast screening centers from the National Health Service Breast Screening Program in England for 1 year (all between December 20, 2012, and November 3, 2014). Three hundred sixty readers participated (mean, 7.8 readers per center)-186 radiologists, 143 radiography advanced practitioners, and 31 breast clinicians, all fully qualified to report mammograms in the NHS breast screening program.INTERVENTIONS: The 2 readers examined each batch of digital mammograms in the same order in the control group and in the opposite order to one another in the intervention group.MAIN OUTCOMES AND MEASURES: The primary outcome was cancer detection rate; secondary outcomes were rates of recall and disagreements between readers.RESULTS: Among 1,194,147 women (mean age, 59.3; SD, 7.49) who had screening mammograms (596,642 in the intervention group; 597,505 in the control group), the images were interpreted in 37,688 batches (median batch size, 35; interquartile range [IQR]; 16-46), with each reader interpreting a median of 176 batches (IQR, 96-278). After completion of all subsequent diagnostic tests, a total of 10,484 cases (0.88%) of breast cancer were detected. There was no significant difference in cancer detection rate with 5272 cancers (0.88%) detected in the intervention group vs 5212 cancers (0.87%) detected in the control group (difference, 0.01% points; 95% CI, -0.02% to 0.04% points; recall rate, 24,681 [4.14%] vs 24,894 [4.17%]; difference, -0.03% points; 95% CI, -0.10% to 0.04% points; or rate of reader disagreements, 20,471 [3.43%] vs 20,793 [3.48%]; difference, -0.05% points; 95% CI, -0.11% to 0.02% points).CONCLUSIONS AND RELEVANCE: Interpretation of batches of mammograms by qualified screening mammography readers using a different order vs the same order for the second reading resulted in no significant difference in rates of detection of breast cancer.TRIAL REGISTRATION: isrctn.org Identifier: ISRCTN46603370.
AB - IMPORTANCE: Interpreting screening mammograms is a difficult repetitive task that can result in missed cancers and false-positive recalls. In the United Kingdom, 2 film readers independently evaluate each mammogram to search for signs of cancer and examine digital mammograms in batches. However, a vigilance decrement (reduced detection rate with time on task) has been observed in similar settings.OBJECTIVE: To determine the effect of changing the order for the second film reader of batches of screening mammograms on rates of breast cancer detection.DESIGN, SETTING, AND PARTICIPANTS: A multicenter, double-blind, cluster randomized clinical trial conducted at 46 specialized breast screening centers from the National Health Service Breast Screening Program in England for 1 year (all between December 20, 2012, and November 3, 2014). Three hundred sixty readers participated (mean, 7.8 readers per center)-186 radiologists, 143 radiography advanced practitioners, and 31 breast clinicians, all fully qualified to report mammograms in the NHS breast screening program.INTERVENTIONS: The 2 readers examined each batch of digital mammograms in the same order in the control group and in the opposite order to one another in the intervention group.MAIN OUTCOMES AND MEASURES: The primary outcome was cancer detection rate; secondary outcomes were rates of recall and disagreements between readers.RESULTS: Among 1,194,147 women (mean age, 59.3; SD, 7.49) who had screening mammograms (596,642 in the intervention group; 597,505 in the control group), the images were interpreted in 37,688 batches (median batch size, 35; interquartile range [IQR]; 16-46), with each reader interpreting a median of 176 batches (IQR, 96-278). After completion of all subsequent diagnostic tests, a total of 10,484 cases (0.88%) of breast cancer were detected. There was no significant difference in cancer detection rate with 5272 cancers (0.88%) detected in the intervention group vs 5212 cancers (0.87%) detected in the control group (difference, 0.01% points; 95% CI, -0.02% to 0.04% points; recall rate, 24,681 [4.14%] vs 24,894 [4.17%]; difference, -0.03% points; 95% CI, -0.10% to 0.04% points; or rate of reader disagreements, 20,471 [3.43%] vs 20,793 [3.48%]; difference, -0.05% points; 95% CI, -0.11% to 0.02% points).CONCLUSIONS AND RELEVANCE: Interpretation of batches of mammograms by qualified screening mammography readers using a different order vs the same order for the second reading resulted in no significant difference in rates of detection of breast cancer.TRIAL REGISTRATION: isrctn.org Identifier: ISRCTN46603370.
KW - Attention
KW - Breast Neoplasms
KW - Double-Blind Method
KW - England
KW - Female
KW - Humans
KW - Logistic Models
KW - Mammography
KW - Middle Aged
KW - Observer Variation
KW - Radiology
KW - Sample Size
KW - Journal Article
KW - Multicenter Study
KW - Randomized Controlled Trial
KW - Research Support, Non-U.S. Gov't
U2 - 10.1001/jama.2016.5257
DO - 10.1001/jama.2016.5257
M3 - Article
C2 - 27163985
SN - 0098-7484
VL - 315
SP - 1956
EP - 1965
JO - JAMA The Journal of the American Medical Association
JF - JAMA The Journal of the American Medical Association
IS - 18
ER -