TY - JOUR
T1 - Tissue inhibitor of metalloproteinse-1 is a marker of diastolic dysfunction using tissue doppler in patients with type 2 diabetes and hypertension
AU - Tayebjee, Muzahir
AU - Lim, Hoong
AU - Nadar, S
AU - Macfadyen, Robert
AU - Lip, Gregory
PY - 2005/1/1
Y1 - 2005/1/1
N2 - BACKGROUND: Tissue inhibitor of metalloproteinase-1 (TIMP-1) is associated with increased fibrosis of the extracellular matrix (ECM). Myocardial stiffness is a feature of diastolic dysfunction. We assessed circulating TIMP-1 as a marker of diastolic dysfunction in patients with type 2 diabetes mellitus (DM) and hypertension, who were compared with healthy controls. METHODS: We recruited 54 patients (43 males; mean age 68 +/- 5 years) with treated type 2 DM (i.e. controlled glycaemia, hypertension, hyperlipidaemia), 35 (30 males; 69 +/- 8 years) treated nondiabetic hypertensives, and 31 healthy controls (18 males; 66 +/- 5 years). Circulating TIMP-1 was measured by ELISA. Using transthoracic echocardiography, the early (E) diastolic mitral inflow velocity was measured with pulse wave Doppler, and the early mitral annular velocity (e'), a recognized index of diastolic relaxation, was measured with tissue Doppler. The E/A ratio was also calculated and isovolumic relaxation time measured. RESULTS: Mean e' levels differed significantly between controls, diabetics and hypertensives (P <0.0001). Circulating TIMP-1 was significantly different between patients and controls (P = 0.006), but there was no statistically significant difference between the DM and hypertension group. In both groups, only e' was negatively correlated with TIMP-1 levels, with a stronger correlation among the hypertensive patients (Spearman r = -0.544, P = 0.001) when compared with the diabetic group (r = -0.341, P = 0.011). CONCLUSION: Diastolic relaxation is impaired in diabetes and hypertensive patients. The relationship between TIMP-1 and e' may reflect increased myocardial fibrosis and consequent diastolic dysfunction, which may be more prominent in hypertension.
AB - BACKGROUND: Tissue inhibitor of metalloproteinase-1 (TIMP-1) is associated with increased fibrosis of the extracellular matrix (ECM). Myocardial stiffness is a feature of diastolic dysfunction. We assessed circulating TIMP-1 as a marker of diastolic dysfunction in patients with type 2 diabetes mellitus (DM) and hypertension, who were compared with healthy controls. METHODS: We recruited 54 patients (43 males; mean age 68 +/- 5 years) with treated type 2 DM (i.e. controlled glycaemia, hypertension, hyperlipidaemia), 35 (30 males; 69 +/- 8 years) treated nondiabetic hypertensives, and 31 healthy controls (18 males; 66 +/- 5 years). Circulating TIMP-1 was measured by ELISA. Using transthoracic echocardiography, the early (E) diastolic mitral inflow velocity was measured with pulse wave Doppler, and the early mitral annular velocity (e'), a recognized index of diastolic relaxation, was measured with tissue Doppler. The E/A ratio was also calculated and isovolumic relaxation time measured. RESULTS: Mean e' levels differed significantly between controls, diabetics and hypertensives (P <0.0001). Circulating TIMP-1 was significantly different between patients and controls (P = 0.006), but there was no statistically significant difference between the DM and hypertension group. In both groups, only e' was negatively correlated with TIMP-1 levels, with a stronger correlation among the hypertensive patients (Spearman r = -0.544, P = 0.001) when compared with the diabetic group (r = -0.341, P = 0.011). CONCLUSION: Diastolic relaxation is impaired in diabetes and hypertensive patients. The relationship between TIMP-1 and e' may reflect increased myocardial fibrosis and consequent diastolic dysfunction, which may be more prominent in hypertension.
U2 - 10.1111/j.1365-2362.2005.01438.x
DO - 10.1111/j.1365-2362.2005.01438.x
M3 - Article
C2 - 15638813
SN - 1365-2362
SN - 1365-2362
SN - 1365-2362
SN - 1365-2362
SN - 1365-2362
SN - 1365-2362
SN - 1365-2362
SN - 1365-2362
SN - 1365-2362
SN - 1365-2362
SN - 1365-2362
VL - 35
SP - 8
EP - 12
JO - European journal of clinical investigation
JF - European journal of clinical investigation
IS - 1
ER -