The effect of clinically relevant thermocycling on the flexural properties of endodontic post materials.

Dominic Stewardson, Adrian Shortall, Peter Marquis

Research output: Contribution to journalArticle

27 Citations (Scopus)

Abstract

OBJECTIVES: It is suggested that fibre-reinforced composite (FRC) posts have lower elastic moduli than metal posts and this will reduce the incidence of root fracture. However, the mechanical properties may be altered in the oral environment. The aims of this study were to determine the effect on the flexural properties of FRC and metal post materials produced by: (1) a thermocycling regime which was clinically relevant and representative of that which would occur during 1 year in the mouth and (2) storage for 1 year at body temperature. METHODS: Nine FRC and two metal post material samples were sealed in polythene sleeves and thermocycled between 10 degrees C and 50 degrees C for 10,000 cycles. Additional samples were stored dry at 37 degrees C for 1 year. The flexural strength and moduli were determined by three-point bending and compared with untreated control samples. RESULTS: Thermocycling and storage at 37 degrees C for 1 year decreased the mean flexural modulus of all materials. This was statistically significant for 8 of 11 materials after thermocycling, and 4 of 11 materials after storage at 37 degrees C (p
Original languageEnglish
Pages (from-to)437-42
Number of pages6
JournalJournal of Dentistry
Volume38
Issue number5
DOIs
Publication statusPublished - 1 May 2010

Keywords

  • Flexural strength
  • Fibre composite
  • Materials testing
  • Flexural modulus
  • Dental restoration failure
  • Metal
  • Thermocycling
  • Endodontic post
  • Elasticity
  • Dentine

Fingerprint

Dive into the research topics of 'The effect of clinically relevant thermocycling on the flexural properties of endodontic post materials.'. Together they form a unique fingerprint.

Cite this