Response of toe-nailed, roof-to-wall connections to extreme wind loads in a full-scale, timber-framed, hip roof

D.J. Henderson, M.J. Morrison, G.A. Kopp

Research output: Contribution to journalArticlepeer-review

23 Citations (Scopus)

Abstract

A full-scale, timber-framed, truss, hip roof was subjected to simulated wind loads. Spatially and temporally varying pressures were applied using an array of 58 Pressure Loading Actuators, together with air-boxes covering all roof surfaces. Load cells were incorporated at the top of the wall frame, just below the top plate, to measure the reactions at the toe-nailed roof-to-wall connections. Changes in influence functions and load sharing between adjacent trusses were observed to occur during withdrawal (slip) of the toe-nail connections caused by large magnitude, short duration peak pressures. Even for relatively small displacements, it was observed that the effective tributary area is substantially increased by the incremental withdrawals. This acts to increase the resilience of the roof by allowing more limber and/or more highly loaded connections to transfer loads to stiffer and/or less highly loaded connections. Influence functions, measured both prior to and following damage, were able to predict this behaviour.
Original languageEnglish
Pages (from-to)1474-1483
JournalEngineering Structures
Volume56
DOIs
Publication statusPublished - 1 Nov 2013

Fingerprint

Dive into the research topics of 'Response of toe-nailed, roof-to-wall connections to extreme wind loads in a full-scale, timber-framed, hip roof'. Together they form a unique fingerprint.

Cite this