Abstract
AIMS
Basic Life Support Guidelines 2005 emphasise the importance of reducing interruptions in chest compressions (no-flow duration) yet at the same time stopped recommending Dual Operator CPR. Dual Operator CPR (where one rescuer does ventilations and one chest compressions) could potentially minimize no-flow duration compared to Single Operator CPR. This study aims to determine if Dual Operator CPR reduces no-flow duration compared to Single Operator CPR.
METHODOLOGY
This was a prospective randomised controlled crossover trial. Medical students were randomised into 'Dual Operator' or 'Single Operator' CPR groups. Both groups performed 4 min of CPR according to their group allocation on a resuscitation manikin before crossing over to perform the other technique one week later.
RESULTS
Fifty participants were recruited. Dual Operator CPR achieved slightly lower no-flow durations than the Single Operator CPR (28.5% (S.D.=3.7) versus 31.6% (S.D.=3.6), P
Original language | English |
---|---|
Pages (from-to) | 1011-4 |
Number of pages | 4 |
Journal | Resuscitation |
Volume | 80 |
Issue number | 9 |
DOIs | |
Publication status | Published - 1 Sept 2009 |