Abstract

In this paper, the condition monitoring technique applied for the evaluation of the status of two hydraulic power units installed in industrial wind turbines is described. The data presented herewith were collected from in-service Vestas V47 and ACCIONA AW1500 wind turbines installed in Greece and Spain respectively. This paper explains the use of motor current signal analysis (MCSA) and historical process data approaches in order to monitor the actual condition of the hydraulic power units under consideration.

Details

Original languageEnglish
Title of host publication10th International Conference on Condition Monitoring and Machinery Failure Prevention Technologies 2013, CM 2013 and MFPT 2013
Publication statusPublished - 1 Jan 2013
Event10th International Conference on Condition Monitoring, CM 2013 and Machinery Failure Prevention Technologies 2013, MFPT 2013 - Krakow, United Kingdom
Duration: 18 Jun 201320 Jun 2013

Conference

Conference10th International Conference on Condition Monitoring, CM 2013 and Machinery Failure Prevention Technologies 2013, MFPT 2013
CountryUnited Kingdom
CityKrakow
Period18/06/1320/06/13

Keywords

  • Condition monitoring, Motor current signal analysis, Wind turbine