Cauda equina syndrome following a lumbar puncture

Alexandra Sinclair, Camille Carroll, B Davies

Research output: Contribution to journalArticle

16 Citations (Scopus)

Abstract

Lumbar puncture (LP), a common diagnostic procedure, is usually associated with low morbidity. We describe the case of a 29-year-old woman who underwent a non-traumatic LP in the setting of normal coagulation. Cauda equina syndrome subsequently developed secondary to an extradural spinal haematoma. Avoidance, identification and management of this uncommon complication are discussed. Iatrogenic cauda equina syndrome following LP is rare, but can cause significant morbidity. Our patient's experience and our review of the literature highlight that: (i) normal coagulation and a non-traumatic LP do not exclude this diagnostic possibility; (ii) early recognition determines the management and prognosis, as 50% of patients remain paraplegic if the condition is identified more than 12 hours after symptom onset; and (iii) neurosurgical intervention can be avoided, despite bladder dysfunction, if there are early signs of recovery.
Original languageEnglish
Pages (from-to)714-716
Number of pages3
JournalJournal of Clinical Neuroscience
Volume16
Issue number5
DOIs
Publication statusPublished - 1 May 2009

Fingerprint

Dive into the research topics of 'Cauda equina syndrome following a lumbar puncture'. Together they form a unique fingerprint.