TY - JOUR
T1 - UV-Vis spectroscopy for monitoring the hydrometallurgical recycling of NdFeB magnets
AU - Widijatmoko, Samuel D.
AU - Brooks, Oliver P.
AU - Walton, Allan
AU - Leeke, Gary A.
N1 - Publisher Copyright:
© 2026 The Author(s)
PY - 2026/11
Y1 - 2026/11
N2 - This study explores the applicability of UV-Vis spectroscopy for monitoring REE composition in NdFeB hydrometallurgical recycling. This study demonstrates that UV-Vis measurement combined with chemometric modelling, without the addition of chromogenic reagents, is sufficient for Nd3+ and Pr3+ quantification. Nitrate and chloride salts of elements commonly found in NdFeB magnets were used to systematically assess the effects of matrix type and concentration on molar absorptivity. A wavelength of 576 nm can be used for univariate calibration of Nd³⁺, yielding a maximum deviation of 16% across eighteen test samples. However, the univariate approach led to substantial errors in predicting Pr3+ concentration. Individual Partial Least Squares (PLS) models were therefore developed for Nd³⁺ and Pr³⁺, trained on 248 datasets across various compositions and matrices. Compared with the univariate approach, PLS regression improved concentration prediction for both species, reducing the root mean square error of prediction by at least half. It should be noted that Fe3+ interferes with Pr3+ prediction, restricting its application to solutions with low Fe3+ content or where its interference has been minimised. Moreover, it was demonstrated that a calibration model built at a given path length can be applied to a flow cell with a different path length using the Beer-Lambert Law, without the need for recalibration. Additionally, PLS Discriminant Analysis (PLS-DA) was shown to be effective for classifying high and low Fe3+ concentration levels, although misclassification may occur in an HNO3 matrix where the absorbance of Fe3+ is less pronounced. Overall, this proof-of-concept study is the first to demonstrate rapid, reagent-free aqueous-phase spectroscopic monitoring for NdFeB hydrometallurgical recycling, using synthetic solutions representative of leachate composition.
AB - This study explores the applicability of UV-Vis spectroscopy for monitoring REE composition in NdFeB hydrometallurgical recycling. This study demonstrates that UV-Vis measurement combined with chemometric modelling, without the addition of chromogenic reagents, is sufficient for Nd3+ and Pr3+ quantification. Nitrate and chloride salts of elements commonly found in NdFeB magnets were used to systematically assess the effects of matrix type and concentration on molar absorptivity. A wavelength of 576 nm can be used for univariate calibration of Nd³⁺, yielding a maximum deviation of 16% across eighteen test samples. However, the univariate approach led to substantial errors in predicting Pr3+ concentration. Individual Partial Least Squares (PLS) models were therefore developed for Nd³⁺ and Pr³⁺, trained on 248 datasets across various compositions and matrices. Compared with the univariate approach, PLS regression improved concentration prediction for both species, reducing the root mean square error of prediction by at least half. It should be noted that Fe3+ interferes with Pr3+ prediction, restricting its application to solutions with low Fe3+ content or where its interference has been minimised. Moreover, it was demonstrated that a calibration model built at a given path length can be applied to a flow cell with a different path length using the Beer-Lambert Law, without the need for recalibration. Additionally, PLS Discriminant Analysis (PLS-DA) was shown to be effective for classifying high and low Fe3+ concentration levels, although misclassification may occur in an HNO3 matrix where the absorbance of Fe3+ is less pronounced. Overall, this proof-of-concept study is the first to demonstrate rapid, reagent-free aqueous-phase spectroscopic monitoring for NdFeB hydrometallurgical recycling, using synthetic solutions representative of leachate composition.
KW - Chemometrics
KW - Process Monitoring
KW - NdFeB Recycling
KW - Rare Earth Elements
KW - Hydrometallurgy
UR - https://www.scopus.com/pages/publications/105049110192
U2 - 10.1016/j.hazadv.2026.101540
DO - 10.1016/j.hazadv.2026.101540
M3 - Article
AN - SCOPUS:105049110192
SN - 2772-4166
VL - 24
JO - Journal of Hazardous Materials Advances
JF - Journal of Hazardous Materials Advances
M1 - 101540
ER -