Abstract
An experimental investigation for the time dependent volumetric heat transfer coefficient of the bubbles type, three-phase direct contact condenser has been carried out utilising a short column (70 cm in total height and 4 cm inner diameter). A 47 cm active height was chosen with five different mass flow rate ratios and three different initial dispersed phase temperatures. Vapour pentane and constant temperature tap water as dispersed and continuous phases were implemented. The results showed that the volumetric heat transfer coefficient decreases with increased time until it almost reaches its steady state conditions. A sharp decrease in the volumetric heat transfer coefficient was found at the beginning of the operation and, diminished over a short time interval. Furthermore, a positive effect of the mass flow rate ratios on the volumetric heat transfer coefficient was noted and this was more pronounced at the beginning of the operation. On the other hand, the volumetric heat transfer coefficient decreased with an increase in the continuous phase mass flow rate and there was no considerable effect of the initial dispersed phase temperatures, which confirms that latent heat transfer is dominant in the process.
Original language | English |
---|---|
Pages (from-to) | 165-170 |
Number of pages | 6 |
Journal | Heat and Mass Transfer/Waerme- und Stoffuebertragung |
Volume | 51 |
Issue number | 2 |
DOIs | |
Publication status | Published - Feb 2014 |
Bibliographical note
Publisher Copyright:© 2014, Springer-Verlag Berlin Heidelberg.
ASJC Scopus subject areas
- Condensed Matter Physics
- Fluid Flow and Transfer Processes