TY - JOUR
T1 - Simultaneous detection of ammonium and nitrate in environmental samples using on ion-selective electrode and comparison with portable colorimetric assays
AU - Choosang, Jittima
AU - Numnuam, Apon
AU - Thavarungkul, Panote
AU - Kanatharana, Proespichaya
AU - Radu, Tanja
AU - Ullah, Sami
AU - Radu, Aleksandar
PY - 2018/10/19
Y1 - 2018/10/19
N2 - © 2018 by the authors. Licensee MDPI, Basel, Switzerland. Simple, robust, and low-cost nitrate-and ammonium-selective electrodes were made using substrate prepared from household materials. We explored phosphonium-based ILs and poly (methyl methacrylate)/poly(decyl methacrylate)(MMA-DMA) copolymer as matrix materials alternative to classical PVC-based membranes. IL-based membranes showed suitability only for nitrate-selective electrode exhibiting linear concentration range between 5.0 × 10−6 and 2.5 × 10−3 M with a detection limit of 5.5 × 10−7 M. On the other hand, MMA-DMA—based membranes showed suitability for both ammonium-and nitrate-selective electrodes, and were successfully applied to detect NO3− and NH4+ in water and soil samples. The proposed ISEs exhibited near-Nernstian potentiometric responses to NO3− and NH4+ with the linear range concentration between 5.0 × 10−5 and 5.0 × 10−2 M (LOD = 11.3 µM) and 5.0 × 10−6 and 1.0 × 10−3 M (LOD = 1.2 µM), respectively. The power of ISEs to detect NO3− and NH4+ in water and soils was tested by comparison with traditional, portable colorimetric techniques. Procedures required for analysis by each technique from the perspective of a non-trained person (e.g., farmer) and the convenience of the use on the field are compared and contrasted.
AB - © 2018 by the authors. Licensee MDPI, Basel, Switzerland. Simple, robust, and low-cost nitrate-and ammonium-selective electrodes were made using substrate prepared from household materials. We explored phosphonium-based ILs and poly (methyl methacrylate)/poly(decyl methacrylate)(MMA-DMA) copolymer as matrix materials alternative to classical PVC-based membranes. IL-based membranes showed suitability only for nitrate-selective electrode exhibiting linear concentration range between 5.0 × 10−6 and 2.5 × 10−3 M with a detection limit of 5.5 × 10−7 M. On the other hand, MMA-DMA—based membranes showed suitability for both ammonium-and nitrate-selective electrodes, and were successfully applied to detect NO3− and NH4+ in water and soil samples. The proposed ISEs exhibited near-Nernstian potentiometric responses to NO3− and NH4+ with the linear range concentration between 5.0 × 10−5 and 5.0 × 10−2 M (LOD = 11.3 µM) and 5.0 × 10−6 and 1.0 × 10−3 M (LOD = 1.2 µM), respectively. The power of ISEs to detect NO3− and NH4+ in water and soils was tested by comparison with traditional, portable colorimetric techniques. Procedures required for analysis by each technique from the perspective of a non-trained person (e.g., farmer) and the convenience of the use on the field are compared and contrasted.
KW - Electrodes versus colorimetric assay
KW - Environmental analysis
KW - Ion-selective electrodes
KW - Soil analysis
UR - http://www.scopus.com/inward/record.url?scp=85055195471&partnerID=8YFLogxK
U2 - 10.3390/s18103555
DO - 10.3390/s18103555
M3 - Article
C2 - 30347779
AN - SCOPUS:85055195471
SN - 1424-8220
VL - 18
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
IS - 10
ER -