Abstract

Background and Objectives: When recruiting participants to a new study developing a clinical prediction model (CPM), sample size calculations are typically conducted before data collection based on sensible assumptions. This leads to a fixed sample size, but if the assumptions are inaccurate, the actual sample size required to develop a reliable model may be higher or even lower. To safeguard against this, adaptive sample size approaches have been proposed, based on sequential evaluation of (changes in) a model's predictive performance. The objective of the study was to illustrate and extend sequential sample size calculations for CPM development by (i) proposing stopping rules for prospective data collection based on minimizing uncertainty (instability) and misclassification of individual-level predictions and (ii) showcasing how it safeguards against inaccurate fixed sample size calculations.

Methods: Using the sequential approach repeats the predefined model development strategy every time a chosen number (eg, 100) of participants are recruited and adequately followed up. At each stage, CPM performance is evaluated using bootstrapping, leading to prediction and classification stability statistics and plots, alongside optimism-adjusted measures of calibration and discrimination. Learning curves display the trend of results against sample size and recruitment is stopped when a chosen stopping rule is met.

Results: Our approach is illustrated for model development of acute kidney injury using (penalized) logistic regression CPMs. Before recruitment based on perceived sensible assumptions, the fixed sample size calculation suggests recruiting 342 patients to minimize overfitting; however, during data collection, the sequential approach reveals that a much larger sample size of 1100 is required to minimize overfitting (targeting a bootstrap-corrected calibration slope ≥0.9). If the stopping rule criteria also target small uncertainty and misclassification probability of individual predictions, the sequential approach suggests an even larger sample size of about 1800.

Conclusion: For CPM development studies involving prospective data collection, a sequential sample size approach allows users to dynamically monitor individual-level prediction and classification instability. This helps determine when enough participants have been recruited and safeguards against using inaccurate assumptions in a sample size calculation before data collection. Engagement with patients and other stakeholders is crucial to identify sensible context-specific stopping rules for robust individual predictions.

Original languageEnglish
Article number112117
Number of pages12
JournalJournal of Clinical Epidemiology
Volume191
Early online date19 Dec 2025
DOIs
Publication statusPublished - Mar 2026

Bibliographical note

Copyright © 2025 The Author(s). Published by Elsevier Inc. All rights reserved.

Keywords

  • Learning Curves
  • Sequential
  • Sample Size
  • Clinical Prediction Models
  • Instability
  • Uncertainty
  • Model Development

Fingerprint

Dive into the research topics of 'Sequential sample size calculations and learning curves safeguard the robust development of a clinical prediction model for individuals'. Together they form a unique fingerprint.

Cite this