Photoplethysmography-based respiratory rate estimation algorithm for health monitoring applications

Talha Iqbal, Adnan Elahi, Sandra Ganly, William Wijns, Atif Shahzad

Research output: Contribution to journalArticlepeer-review

45 Downloads (Pure)

Abstract

Purpose: Respiratory rate can provide auxiliary information on the physiological changes within the human body, such as physical and emotional stress. In a clinical setup, the abnormal respiratory rate can be indicative of the deterioration of the patient's condition. Most of the existing algorithms for the estimation of respiratory rate using photoplethysmography (PPG) are sensitive to external noise and may require the selection of certain algorithm-specific parameters, through the trial-and-error method. Methods: This paper proposes a new algorithm to estimate the respiratory rate using a photoplethysmography sensor signal for health monitoring. The algorithm is resistant to signal loss and can handle low-quality signals from the sensor. It combines selective windowing, preprocessing and signal conditioning, modified Welch filtering and postprocessing to achieve high accuracy and robustness to noise. Results: The Mean Absolute Error and the Root Mean Square Error of the proposed algorithm, with the optimal signal window size, are determined to be 2.05 breaths count per minute and 2.47 breaths count per minute, respectively, when tested on a publicly available dataset. These results present a significant improvement in accuracy over previously reported methods. The proposed algorithm achieved comparable results to the existing algorithms in the literature on the BIDMC dataset (containing data of 53 subjects, each recorded for 8 min) for other signal window sizes. Conclusion: The results endorse that integration of the proposed algorithm to a commercially available pulse oximetry device would expand its functionality from the measurement of oxygen saturation level and heart rate to the continuous measurement of the respiratory rate with good efficiency at home and in a clinical setting.

Original languageEnglish
Pages (from-to)242-252
Number of pages11
JournalJournal of Medical and Biological Engineering
Volume42
Issue number2
DOIs
Publication statusPublished - 7 Apr 2022

Bibliographical note

Funding Information:
Open Access funding provided by the IReL Consortium. This publication has emanated from research conducted with the financial support of Science Foundation Ireland under Grant number [15/RP/2765]. For the purpose of Open Access, the author has applied a CC BY public copyright license to any Author Accepted Manuscript version arising from this submission. A.S. acknowledges financial support from the University of Birmingham Dynamic Investment Fund.

Publisher Copyright:
© 2022, The Author(s).

Keywords

  • Adaptive estimation
  • Algorithms
  • Health monitoring
  • Photoplethysmography
  • Respiratory rate
  • Wearable sensors

ASJC Scopus subject areas

  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Photoplethysmography-based respiratory rate estimation algorithm for health monitoring applications'. Together they form a unique fingerprint.

Cite this