Abstract
There is currently no OEL for diesel fumes in the UK. This study reports parallel measurements of airborne levels of diesel fume pollutants in nine distribution depots where diesel powered fork-lift trucks (FLTs) were in use. Correlations between individual pollutants are assessed as well as their spatial distribution. Samples were collected on board FLTs and at background positions at nine distribution depots. Substances measured and the range of exposures by site were: respirable dust (n = 76) GM
Original language | English |
---|---|
Pages (from-to) | 369-376 |
Number of pages | 8 |
Journal | Annals of Occupational Hygiene |
Volume | 48 |
Early online date | 2 Mar 2004 |
DOIs | |
Publication status | Published - 2 Mar 2004 |
Keywords
- fork lift trucks
- diesel exhaust fumes
- polycyclic aromatic hydrocarbons
- elemental carbon
- ultrafine particles