TY - GEN
T1 - Modelling silicone finger joint implant
AU - Salamat, Amir Hossein
AU - Shepherd, Duncan E.T.
PY - 2010
Y1 - 2010
N2 - There are different reasons which may result in a need for finger joint arthroplasty, the main reason is thought to be rheumatoid arthritis (RA). Geometric models of the Swanson and the Neuflex implants which are two of the most commonly used implants were constructed, and meshed after a convergence test and refinements were made in critical regions. The main objective of this study is to use finite element analysis (FEA) to simulate conditions (using Abaqus/CAE) in which the implants are imposed to; these conditions are mainly flexion and extension of the implants [1] Finite element studies are done on issues of stress/strain concentration and also effects of a crack on the implant are analysed. The two chosen designs will be evaluated and compared analytically; the results of this study will be compared to that of literature and in-vitro/in-vivo results (where possible). The effect of the difference in the geometry of the two implants is also considered. In order to achieve these goals three-dimensional (3D) and two-dimensional (2D) models were constructed in FEA software. It was found that such implants tend to fail at their hinge-stem interface, with the main reason being their material rather than their design.
AB - There are different reasons which may result in a need for finger joint arthroplasty, the main reason is thought to be rheumatoid arthritis (RA). Geometric models of the Swanson and the Neuflex implants which are two of the most commonly used implants were constructed, and meshed after a convergence test and refinements were made in critical regions. The main objective of this study is to use finite element analysis (FEA) to simulate conditions (using Abaqus/CAE) in which the implants are imposed to; these conditions are mainly flexion and extension of the implants [1] Finite element studies are done on issues of stress/strain concentration and also effects of a crack on the implant are analysed. The two chosen designs will be evaluated and compared analytically; the results of this study will be compared to that of literature and in-vitro/in-vivo results (where possible). The effect of the difference in the geometry of the two implants is also considered. In order to achieve these goals three-dimensional (3D) and two-dimensional (2D) models were constructed in FEA software. It was found that such implants tend to fail at their hinge-stem interface, with the main reason being their material rather than their design.
KW - Crack growth
KW - FEA
KW - MCP joint
KW - Modelling
KW - Silicone
UR - https://www.scopus.com/pages/publications/79951764546
U2 - 10.1109/ICBME.2010.5705007
DO - 10.1109/ICBME.2010.5705007
M3 - Conference contribution
AN - SCOPUS:79951764546
SN - 9781424474844
T3 - 2010 17th Iranian Conference of Biomedical Engineering, ICBME 2010 - Proceedings
BT - 2010 17th Iranian Conference of Biomedical Engineering, ICBME 2010 - Proceedings
T2 - 17th Iranian Conference in Biomedical Engineering, ICBME 2010
Y2 - 3 November 2010 through 4 November 2010
ER -