TY - JOUR
T1 - Integrated system for temperature-controlled fast protein liquid chromatography. IV. Continuous ‘one-column’ ‘low-salt’ hydrophobic interaction chromatography
AU - Brean, Alexander
AU - Overton, Tim
AU - Bracewell, Daniel
AU - Franzreb, Matthias
AU - Thomas, Owen
PY - 2024/8/30
Y1 - 2024/8/30
N2 - Systematic development of a temperature-controlled isocratic process for one-column low-salt hydrophobic interaction chromatography (HIC) of proteins employing a travelling cooling zone reactor (TCZR) system, is described. Batch binding and confocal scanning microscopy were employed to define process conditions for temperature-reversible binding of bovine serum albumin (BSA) which were validated in pulse-response temperature switching HIC experiments, before transferring to TCZR-HIC. A thin-walled stainless-steel column mounted with a movable assembly of copper blocks and Peltier elements (travelling cooling zone, TCZ) was used for TCZR-HIC. In pulse-response TCZR-HIC, 12 TCZ movements along the column desorbed 86.3% of the applied BSA monomers in 95.3% purity depleted >6-fold in 2-4mers and nearly 260-fold in higher molecular weight (HMW) species. For continuous TCZR-HIC, the TCZ was moved 49-58 times during uninterrupted loading of BSA feeds at 0.25, 0.5 or 1 mg·mL-1. Each TCZ movement generated a sharp symmetrical elution peak. In the best case, (condition 1: 0.25 mg·mL-1 BSA; >17 mg BSA applied per mL of bed) the height of TCZ elution peaks approached pseudo-steady midway through the loading phase with no rise in baseline UV280 signal between peaks. Peak composition remained constant averaging 94.4% monomer, 5.6% 2-4 mers and <0.05% HMW. Monomers were recovered in quantitative yield depleted >3.1 fold in 2-4 mers and 92-fold in HMW species cf. the feed (63.6% monomers, 21.8% 2-4 mers, 14.6% HMW). However, increasing the BSA concentration to 1 mg·mL-1 (condition 2) or employing a fouled HIC column with 0.5 mg·mL-1 BSA (condition 3) compromised monomer purification performance.
AB - Systematic development of a temperature-controlled isocratic process for one-column low-salt hydrophobic interaction chromatography (HIC) of proteins employing a travelling cooling zone reactor (TCZR) system, is described. Batch binding and confocal scanning microscopy were employed to define process conditions for temperature-reversible binding of bovine serum albumin (BSA) which were validated in pulse-response temperature switching HIC experiments, before transferring to TCZR-HIC. A thin-walled stainless-steel column mounted with a movable assembly of copper blocks and Peltier elements (travelling cooling zone, TCZ) was used for TCZR-HIC. In pulse-response TCZR-HIC, 12 TCZ movements along the column desorbed 86.3% of the applied BSA monomers in 95.3% purity depleted >6-fold in 2-4mers and nearly 260-fold in higher molecular weight (HMW) species. For continuous TCZR-HIC, the TCZ was moved 49-58 times during uninterrupted loading of BSA feeds at 0.25, 0.5 or 1 mg·mL-1. Each TCZ movement generated a sharp symmetrical elution peak. In the best case, (condition 1: 0.25 mg·mL-1 BSA; >17 mg BSA applied per mL of bed) the height of TCZ elution peaks approached pseudo-steady midway through the loading phase with no rise in baseline UV280 signal between peaks. Peak composition remained constant averaging 94.4% monomer, 5.6% 2-4 mers and <0.05% HMW. Monomers were recovered in quantitative yield depleted >3.1 fold in 2-4 mers and 92-fold in HMW species cf. the feed (63.6% monomers, 21.8% 2-4 mers, 14.6% HMW). However, increasing the BSA concentration to 1 mg·mL-1 (condition 2) or employing a fouled HIC column with 0.5 mg·mL-1 BSA (condition 3) compromised monomer purification performance.
KW - Bioseparation
KW - Bovine serum albumin, BSA
KW - Green and sustainable
KW - Protein aggregates
KW - Purification
U2 - 10.1016/j.chroma.2024.465212
DO - 10.1016/j.chroma.2024.465212
M3 - Article
C2 - 39068770
SN - 0021-9673
VL - 1731
JO - Journal of Chromatography A
JF - Journal of Chromatography A
M1 - 465212
ER -