Focused ion beam fabrication of thermally actuated bimorph cantilevers

Jason Teng, Philip Prewett

Research output: Contribution to journalArticle

20 Citations (Scopus)

Abstract

Focused ion beam (FIB) technology was used to fabricate thermally actuated cantilever arrays using silicon nitride membrane chips for microelectromechanical systems (MEMS) applications. Sequential modification and test is made possible by the dualbeam FIB/SEM. A fabrication route based largely on the use of FIB etch and deposition steps applied to a silicon nitride membrane chip resulted in the formation of readily released bimorph structures with lengths <10 mu m. Device deflection sensitivity better than 500 nm/mW was observed. Short-circuiting and hence non-functionality of some devices was attributed to the platinum halo overlap between deposited tracks, which limits the potential for miniaturisation of FIB-MEMS prototypes. Potential applications for these cantilever arrays include scanning probe microscope (SPM) systems and resonant gas sensors. (C) 2005 Elsevier B.V. All Rights reserved.
Original languageEnglish
Pages (from-to)608-613
Number of pages6
JournalSensors and Actuators A: Physical
Volume123-124
DOIs
Publication statusPublished - 23 Sept 2005

Keywords

  • cantilever
  • MEMS prototyping
  • bimorph
  • FIB

Fingerprint

Dive into the research topics of 'Focused ion beam fabrication of thermally actuated bimorph cantilevers'. Together they form a unique fingerprint.