Projects per year
Abstract
This paper outlines the centralized design and production of the ultra-high-vacuum sidearm and laser-stabilization systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilization, and on the loading rate for the 3D magneto-optical trap are presented. Streamlining the design and production of the sidearm and laser stabilization systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.
Original language | English |
---|---|
Article number | 014409 |
Number of pages | 17 |
Journal | AVS Quantum Science |
Volume | 6 |
Issue number | 1 |
DOIs | |
Publication status | Published - 14 Mar 2024 |
Fingerprint
Dive into the research topics of 'Centralized design and production of the ultra-high vacuum and laser-stabilization systems for the AION ultra-cold strontium laboratories'. Together they form a unique fingerprint.-
AION: A UK Atom Interferometer Observatory and Network
Holynski, M., Singh, Y. & Bongs, K.
SCIENCE & TECHNOLOGY FACILITIES COUNCIL
1/05/21 → 31/03/25
Project: Research Councils
-
Differential atom interferometry and velocity selection using the clock transition of strontium atoms for AION
SCIENCE & TECHNOLOGY FACILITIES COUNCIL
1/09/22 → 31/08/24