TY - JOUR
T1 - Abnormal retinal vascular function and lipid levels in a sample of healthy UK South Asians
AU - Patel, SR
AU - Bellary, S
AU - Qin, L
AU - Gill, Paramjit
AU - Taheri, Shahrad
AU - Heitmar, R
AU - Gibson, Jonathan
AU - Gherghel, D
PY - 2011/11/1
Y1 - 2011/11/1
N2 - Background/aims To investigate ethnic differences in retinal vascular function and their relationship to traditional risk indicators for cardiovascular disease (CVD).
Methods A total of 90 normoglycaemic subjects (45 South Asian (SA) and 45 age- and gender-matched white Europeans (WEs)) were recruited for the present study. Retinal vessel reactivity to flickering light was assessed by means of the dynamic retinal vessel analyser according to a modified protocol. Fasting plasma glucose, triglycerides (TG), total, LDL and HDL cholesterol were also measured in all individuals.
Results SA individuals showed higher fasting triglyceride (p=0.001) and lower HDL levels (p=0.007), leading to a higher TG: HDL-C ratio (p=0.001) than age- matched WE subjects. Additionally, in SAs, the retinal arterial reaction time in response to flicker stimulation was significantly longer in the last flicker cycle than in the WEs (p=0.039), and this change correlated positively with measured plasma TG levels (r=0.60; p=0.01). No such relationship was observed in the WEs (p>0.05).
Conclusion Even in the absence of overt vascular disease, in otherwise healthy SAs there are potential signs of retinal vascular function impairment that correlates with established plasma markers for CVD risk.
AB - Background/aims To investigate ethnic differences in retinal vascular function and their relationship to traditional risk indicators for cardiovascular disease (CVD).
Methods A total of 90 normoglycaemic subjects (45 South Asian (SA) and 45 age- and gender-matched white Europeans (WEs)) were recruited for the present study. Retinal vessel reactivity to flickering light was assessed by means of the dynamic retinal vessel analyser according to a modified protocol. Fasting plasma glucose, triglycerides (TG), total, LDL and HDL cholesterol were also measured in all individuals.
Results SA individuals showed higher fasting triglyceride (p=0.001) and lower HDL levels (p=0.007), leading to a higher TG: HDL-C ratio (p=0.001) than age- matched WE subjects. Additionally, in SAs, the retinal arterial reaction time in response to flicker stimulation was significantly longer in the last flicker cycle than in the WEs (p=0.039), and this change correlated positively with measured plasma TG levels (r=0.60; p=0.01). No such relationship was observed in the WEs (p>0.05).
Conclusion Even in the absence of overt vascular disease, in otherwise healthy SAs there are potential signs of retinal vascular function impairment that correlates with established plasma markers for CVD risk.
U2 - 10.1136/bjo.2010.201665
DO - 10.1136/bjo.2010.201665
M3 - Article
C2 - 21362772
SN - 0007-1161
VL - 95
SP - 1573
EP - 1576
JO - British Journal of Ophthalmology
JF - British Journal of Ophthalmology
IS - 11
ER -